Study reveals TiN coating significantly reduces corrosion in titanium, implying potential for medical applications.
The TiN coating obtained by vacuum-arc spraying on the surface of commercially pure VT1-0 titanium and thermodiffusion saturation in a nitrogen atmosphere was studied. The coatings were evaluated by electrochemical methods for determining their corrosion resistance in Ringer physiological solution. It was found that the TiN coating deposited on untreated titanium has twice lower corrosion current density of untreated titanium, while the nitrided surface, without and with the TiN coating, has a lower corrosion current density by only 6 and 20% less, respectively. The TiN coating deposited on untreated titanium has the highest corrosion resistance, and the nitrided surface has the lowest corrosion resistance. Despite this ranking, the corrosion resistance of all investigated coatings is higher than that of the untreated VT1-0 titanium. Therefore, owing to the high electrochemical stability in Ringer solution, which contains Cl– ions, the simple surface modification technology, and its non-toxicity, nitride coatings have a promising application in medicine.