Assessment of assistive force profiles reveals improved muscle activity reduction in half-squatting postures, indicating potential for agricultural applications.
To enable the practical application of passive back-support exoskeletons employing pneumatic artificial muscles (PAMs) in tasks such as agricultural work, we evaluated their assistive effectiveness in a half-squatting posture with a staggered stance. In this context, assistive force profiles were adjusted according to body posture to achieve more effective support. The targeted assistive force profile was designed to be continuously active from the standing to the half-squatting position, with minimal variation across this range. The assistive force profile was developed based on a PAM contractile force model and implemented using a cam mechanism. The effectiveness of assistance was assessed by measuring body flexion angles and erector spinae muscle activity during lifting and carrying tasks. The results showed that the assistive effect was greater on the side with the forward leg. Compared to the condition without exoskeleton assistance, the conventional pulley-based system reduced muscle activity by approximately 20% whereas the cam-based system achieved a reduction of approximately 30%.
No takes yet. Share an insight, caveat, or question.
Saito et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: