Experimental analysis reveals optimal stagger angle of 60° improves torque and power coefficients in Savonius turbines, indicating the effectiveness of overlap blades.
The previous Savonius wind turbine studies have proved that overlap modifications to conventional blades can improve turbine performance. With these conventional blades, the performance is less optimum because the drag force generated by turbine's rotation is still high. Based on this condition, this experiment is conducted by modifying Savonius wind turbine with overlap blades using Myring equation n = 1. Its blade profile is made half-elliptical to reduce drag force. Diameter and height of the turbine are 400 mm with 0.3 overlap ratio. The ratio of cylinder diameter (ds/D) is 0.4, and the ratio of cylinder center distance (S/d) is 1.7. Experiments are conducted by varying stagger angles of circular cylinder in front of returning blade are 45°, 50°, 55°, and 60° with velocity 5 m/s. The final results show that the best performance improvement of the turbine occurs at 60° stagger angle. The increase in torque coefficient is 4.95% and power coefficient is 20.16% to overlap Savonius wind turbine with myring n = 1 with no circular cylinder.