September 10, 2025Micromachines4 citationsOpen Access

Design and Evaluation of a Capacitive Micromachined Ultrasonic Transducer(CMUT) Linear Array System for Thickness Measurement of Marine Structures Under Varying Environmental Conditions

View Full Paper
CHChangde HeNorth University of ChinaMLMengke LuoMacau University of Science and TechnologyHCHanchi ChaiNorth University of China

Key Points

  • The CMUT array achieved a transmitting sensitivity of 146.82 dB and a receiving sensitivity of −229.55 dB.
  • Thickness measurement error remained within ±0.1 mm under varying environmental conditions, ensuring accuracy.
  • Systematic experiments tested CMUT performance under different water temperatures and salinities, proving environmental adaptability.
  • Results validate the use of CMUT-based systems for non-destructive evaluation of marine infrastructure.

Abstract

This paper presents the design, fabrication, and experimental evaluation of a capacitive micromachined ultrasonic transducer (CMUT) linear array for non-contact thickness measurement of marine engineering structures. A 16-element CMUT array was fabricated using a silicon–silicon wafer bonding process, and encapsulated in polyurethane to ensure acoustic impedance matching and environmental protection in underwater conditions. The acoustic performance of the encapsulated CMUT was characterized using standard piezoelectric transducers as reference. The array achieved a transmitting sensitivity of 146.82 dB and a receiving sensitivity of −229.55 dB at 1 MHz. A complete thickness detection system was developed by integrating the CMUT array with a custom transceiver circuit and implementing a time-of-flight (ToF) measurement algorithm. To evaluate environmental robustness, systematic experiments were conducted under varying water temperatures and salinity levels. The results demonstrate that the absolute thickness measurement error remains within ±0.1 mm under all tested conditions, satisfying the accuracy requirements for marine structural health monitoring. The results validate the feasibility of CMUT-based systems for precise and stable thickness measurement in underwater environments, and support their application in non-destructive evaluation of marine infrastructure.