September 17, 2025Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition0 citations

Fast Gradient Ascent Pulse Engineering for parallel transmission pulse design in the small and large tip angle regimes

View Full Paper
NDNatalia DudyshevaUniversité Paris-SaclayJBJoseph BrégeatFMFranck MauconduitUniversité Paris-Sud

Key Points

  • FastGRAPE offers flip angle accuracy comparable to GRAPE and computation time similar to kT-points, enhancing pulse design efficiency.
  • For short STA excitation, fastGRAPE provides performance on par with GRAPE, outperforming kT-points in pulse optimization.
  • The approach utilizes Bloch simulation and in vivo acquisitions, applying methods on both commercial and custom pTX RF coils.
  • FastGRAPE presents a promising strategy for dynamic RF shimming, optimizing balance between accuracy and speed.

Abstract

Motivation: Dynamic RF shimming in pTX at UHF faces two limitations: lengthy computational time of the GRAPE method or lack of precision of parametric approaches (e.g. kT-points). Goal(s): To validate an alternative pulse parameterization, fastGRAPE, potentially offering a better trade-off between the performance and computational speed. Approach: We compare GRAPE, fastGRAPE, and kT-point online and offline pulse designs for a commercial and a custom pTX RF coils at 7T using Bloch simulation and in vivo acquisitions. Results: For short STA excitation, fastGRAPE yields comparable performances to GRAPE and outperforms kT-points. For inversion with the custom coil, online fastGRAPE provides the best flip angle accuracy. Impact: With a flip angle accuracy comparable to GRAPE and a computation time comparable to kT-points, fastGRAPE presents a promising strategy both for online and offline dynamic RF shimming.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Dudysheva et al. (2025) studied this question.

synapsesocial.com/papers/68d4597b31b076d99fa5cb17https://doi.org/10.58530/2025/3439
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Calibration-free GRAPE pTx pulses for homogeneous spatial-selective excitation at 7T2026
  2. 2A Versatile Toolbox for Rapid, Joint Design of pTx RF and Gradient Pulses Using Pytorch's Autodifferentiation2024
  3. 3Multiphoton parallel transmission (MP‐pTx): Pulse design methods and numerical validation2024 · 2 citations
  4. 4RF pulse optimization for robust excitation in 31P magnetization transfer spectroscopy2024
  5. 5In-vivo 3D liver imaging at 7T using kT-point pTx pulses and a 32-Tx-channel whole-body RF antenna array2024 · 1 citations