September 18, 2025Physics in Medicine and Biology4 citations

Enhanced SVD filter based on singular vector subspace denoising improves ultrafast ultrasound microvascular imaging performance

View Full Paper
YXYu XiaJZJiabin ZhangDCDaichao Chen

Key Points

  • The eSVD filter improves microvascular imaging contrast by effectively separating blood flow from noise.
  • In mouse brain imaging, the eSVD filter enhances CNR by 8.36 dB and SNR by 7.92 dB compared to traditional methods.
  • Qualitative and quantitative results demonstrate that the eSVD filter provides superior imaging details and contrast in uPDI.
  • The enhanced SVD method is promising for diagnosing diseases related to changes in microvascular structures.

Abstract

Abstract Ultrafast ultrasound imaging can significantly improve the ability of ultrasound for microvascular visualization. Clutter filtering through Singular Value Decomposition (SVD)-based filter remains a pivotal step in Ultrafast ultrasound imaging. However, the current hard threshold-based SVD filter cannot completely separate blood flow from noise on the basis of filtering tissue clutter, resulting in low contrast in microvascular imaging. This paper proposes a novel enhanced SVD (eSVD) filter to enhance blood flow signals and suppress noise while filtering clutter. The proposed method innovatively partitions spatial singular vectors into multiple blood flow subspaces followed by subspace-specific weighted reconstruction to amplify blood signatures. We validate the effectiveness of the eSVD filter in contrast-free ultrafast power Doppler imaging (uPDI), contrast-enhanced uPDI, and ultrasound localization microscopy (ULM) imaging experiments. Qualitative and quantitative experimental results show that compared with the hard threshold-based SVD filter, our method can significantly improve the contrast between vessels and background, and highlight the details of microvessels. Compared with the adaptive SVD filter based on the spatial similarity matrix, our eSVD filter improves CNR by 8.36 dB, SNR by 7.92 dB, and BCR by 15.47 dB in the uPDI of mouse contrast-free brain. In the ULM of mouse tumor, our eSVD filter improves the global spatial resolution by about 6 μm, from 34.49 μm to 28.15 μm. The proposed eSVD filter essentially improves the performance of ultrafast ultrasound microvascular imaging and has the potential for the diagnosis of many diseases related to microvessel change.