This method achieves sub-MHz measurement uncertainty in fiber optics, suggesting precision in signal detection.
We propose a fast Brillouin optical time-domain reflectometry scheme using simplex coding and coherent detection. Brillouin frequency shift measurement uncertainty of 0.38 MHz is achieved for 10 km fiber and 4.0 m spatial resolution.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2025) studied this question.