This paper reports a novel fiber-optic bolometer design achieving superior sensitivity and noise performance, with implications for plasma diagnostics.
Fiber-optic bolometers (FOBs) based on a fiber-tipped silicon Fabry-Perot (FP) interferometric temperature sensor and a gold disk absorber have been shown as an attractive alternative to conventional resistive bolometers for plasma radiation measurement in fusion devices. Either a high-finesse FP or a low-finesse FP can be used, each with trade-offs between noise performance and fabrication complexity. In this paper, we present an FOB design that overcomes these limitations by combining a low-finesse long silicon FP cavity with a large gold disk absorber to achieve enhanced sensitivity and noise performance without increasing the fabrication complexity and the time constant. We also demonstrated a fabrication method for the sensor head facilitated by a heat release tape and precise laser heating. Our FOB demonstrates a temperature resolution of 0.08 mK, a cooling time constant of 230 ms, and a noise equivalent power density of 0.015 W/m². This represents an 8-fold improvement over previous high-finesse FOBs and 26-fold improvement over previous low-finesse FOBs with similar demodulation bandwidth and similar cooling time constants.