Answers are grounded in this paper and cite their sources.
Simulation-based analysis identifies optimal voltage settings for DC railways, suggesting energy efficiency improvements through PSO.
This article discusses voltage level modifications in urban mass transit traction substations, focusing on DC railway substations, to reduce power consumption and improve energy efficiency. Substation voltage settings are usually adjusted by a skilled designer using practical judgment and design acumen. To maximize operations, all traction substation voltage levels are automatically adjusted to the same value. This arrangement works well and may not have affected the power supply system. This design often causes operations to deviate from optimal performance, perhaps reducing energy efficiency. This research seeks to determine the optimal traction substation voltage setting that minimizes total energy consumption of DC electric railways. A simulation‐based approach is applied using train movement data and voltage variation scenarios. The proposed designs are linear, V ‐shaped, and fixed‐voltage. Additionally, particle swarm optimization (PSO) is an effective way to find the best design. The Bangkok Transit System (BTS) Sukhumvit line is used for testing. Reduction by the linear framework, energy consumption may be 2.341% lower than the base case. By the PSO, the results in 30 trial test runs suggest a 6.107% energy consumption reduction from baseline.
No takes yet. Share an insight, caveat, or question.
Saikong et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: