Answers are grounded in this paper and cite their sources.
Comparative analysis of left ventricular ejection fraction using echocardiography, CCT, and CMR in SARS-CoV2 patients, highlighting significant differences.
Objective The aim of the study was to compare the assessment of left ventricular ejection fraction (LVEF) performed using echocardiography, cardiac computed tomography (CCT) and cardiac magnetic resonance (CMR) in patients after SARS-CoV2 infection. Material and methods The study group consisted of 108 patients (54.17 ± 8.11 years, 52% women and 48% men) with a history of SARS-CoV-2 infection. In all patients, echocardiography, CCT and CMR examinations were performed based on the guidelines of scientific societies. In echocardiography, LVEF (LVEF ECHO ) was determined from the apical 4-chamber and 2-chamber views, with the biplane Simpson’s method. In CCT, LVEF was assessed based on the contours of the left ventricular endocardium and epicardium in multiplanar reconstructions (MPR) from the multiphase of the entire cardiac cycle, which was part of the protocol of coronary computed tomography angiography performed with retrospective ECG gating with radiation dose modulation (LVEF CCT1 ). Additionally, in CCT, LVEF was assessed based on the left ventricular blood pool in the above reconstructions (LVEF CCT2 ). For the assessment of LVEF in CMR (LVEF CMR ), a standard volumetric method was used using CINE sequence images in the 2-chamber projection in the long axis and in the short axis of the left ventricle. The coefficient of variation of measurements (CV) was calculated for each pair of LVEF measurements, as well as for all LVEF measurements. Results The mean LVEF measurement values in the study group were 59.72% ± 7.39% for LVEF ECHO , 63.36% ± 9.32% for LVEF CCT1 , 64.5% ± 9.79% for LVEF CCT2 , and 60.84% ± 9.29% for LVEF CMR . LVEF ECHO was statistically significantly lower than LVEF CCT1 and LVEF CCT2 . LVEF CMR was also statistically significantly lower than LVEF CCT1 and LVEF CCT2 . CV for all LVEF measurements was 4.61% ± 1.73%. When comparing pairs of LVEF measurements, the lowest CV was observed for LVEF CCT1 and LVEF CCT2 (2.97% ± 2.64%), while the highest CV was observed for LVEF ECHO and LVEF CCT2 (6.04% ± 3.39%). When comparing LVEF to the gold standard of assessment, i.e., LVEF CMR , the most consistent measurements were obtained for LVEF ECHO (CV 3.00% ± 2.01%), while the least consistent measurements were obtained for CCT2 (4.65% ± 3.24%). A positive correlation was found between body mass index and CV of LVEF measurements (r = 0.44, p < 0.05), as well as between heart rate (during CCT) and CV of LVEF measurements (r = 0.37, p < 0.05). Furthermore, a negative correlation existed between LVEF measured by ECHO and CV of LVEF measurements in this group of patients (r = - 0.27, p < 0.05). Conclusion There are statistically significant differences in left ventricular ejection fraction measurements in patients with a history of SARS-CoV-2 infection using different cardiac imaging modalities. Cardiac computed tomography overestimates LVEF compared to echocardiography and cardiac magnetic resonance imaging. Patients with abnormal body mass, suboptimal heart rate and reduced left ventricular systolic function are subgroups with increased variability of LVEF measurements in different cardiac imaging modalities.
No takes yet. Share an insight, caveat, or question.
Gać et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: