Effect of Blowing Configurations on Heat Transfer Augmentation With Multihole Sweeping Jet Film Cooling

View Full Paper
HSHitesh SharmaKKK. Suresh KumarARArnab Roy

Key Points

  • Increased blowing ratio of the middle cooling hole can reduce heat transfer augmentation by 9% while maintaining effectiveness.
  • The study identifies the phenomenon of 'blobbing', where coolant streams escape in lumps, affecting surface cooling.
  • Non-synchronized interactions of sweeping jets create irregular coolant distributions over the target surface.
  • Increasing flow rate with straight blowing negatively impacts leading-edge film cooling effectiveness.

Abstract

Abstract The use of sweeping jets as a coolant stream is a recent addition to the field of film cooling, gaining popularity due to its improvement in performance over steady jets. In this study, numerical investigations were performed to study effects of various blowing configurations on the multihole sweeping jet film cooling at leading edge of an HP turbine NGV. Three sweeping jets were studied with transitional periodicity, and blowing ratio was varied as BR = 0.5, 0.75, and 1.0 in two configurations. When the BR of the middle hole was increased, keeping others the same, it was termed as ‘jet focusing’, and when the BR of all the holes was increased, it was termed as ‘straight blowing’. A detailed discussion of heat transfer augmentation results is presented along with the unsteady aerodynamics and thermal fields produced by a row of sweeping jets. It was observed that sweeping jets placed in a row interact in a non-synchronized and highly unpredictable manner. This results in an asymmetrical distribution of coolant over the target surface. A new feature of reversed hole configuration was found where the coolant stream comes out of the cooling hole in the form of lumps of cold fluid. This phenomenon was termed ‘blobbing’. The results also showed that jet focusing may result in a 9% reduction in heat transfer augmentation without affecting film cooling effectiveness in leading edge region. Increasing the coolant flow rate with straight blowing proves to be detrimental to leading-edge film cooling.