PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
September 27, 2025Journal of Robotic Surgery5 citationsOpen Access

Multicenter evaluation of the DEXTER® Robotic Surgery System for Total Hysterectomy with Adnexal Surgery

View Full Paper
MGMarietta GulzMBMarie-Lucile BodetMSMatthias Streich

Key Points

  • Robotic-assisted hysterectomy performed without intraoperative complications or conversions.
  • Fifty-two patients enrolled across four European centers showed a mean operative time of 121.9 minutes.
  • The study confirmed the safety of DEXTER with one major Clavien–Dindo IIIb complication recorded.
  • Results support expanding access to robotic-assisted surgery in different clinical settings.

Abstract

Abstract Minimally invasive hysterectomy is the preferred surgical approach for benign gynecologic conditions. The DEXTER® Robotic Surgery System was developed to address the limitations of conventional robotic systems, offering a mobile, modular, and accessible alternative adaptable to various surgical environments. This prospective, multicenter, single-arm study evaluated the clinical performance and early postoperative safety of the robotic-assisted hysterectomy with adnexal surgery for benign indications with DEXTER. The primary endpoints were short-term safety, assessed by the occurrence of Clavien–Dindo grade ≥ III adverse events up to 42 days postoperatively, and procedural success without conversion to laparoscopy or open surgery. Fifty-two patients were enrolled across four European centers—one university hospital and three community hospitals. All procedures were successfully completed without intraoperative complications or conversions. The mean total skin-to-skin operative time was 121.9 ± 42.7 min, and the mean estimated blood loss was 87.8 ± 93.8 mL. The system also demonstrated efficient setup with a mean docking time of 3.8 ± 1.3 min, as well as the feasibility of a three-trocar technique for minimal scarring and potential for outpatient application in select cases. The mean time to discharge was 2.0 ± 0.9 days. One major Clavien–Dindo IIIb complication occurred. No device-related adverse events were reported. These results confirm the safety and performance of DEXTER in robotic-assisted hysterectomy and support its role in expanding access to robotic-assisted surgery in diverse clinical settings. Trial registration : ClinicalTrials.gov NCT06473675.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Gulz et al. (2025) studied this question.

synapsesocial.com/papers/68d7e84439bbb06045426c97https://doi.org/10.1007/s11701-025-02647-0
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1The first robotic-assisted hysterectomy below the bikini line with the Dexter robotic system™2024 · 13 citations
  2. 2A Comparison of Total Laparoscopic Hysterectomy to Robotically Assisted Hysterectomy: Surgical Outcomes in a Community Practice2008 · 269 citations
  3. 3Validate robot-assisted total laparoscopic hysterectomy with four equally-spaced ports without an assistant port2024 · 4 citations
  4. 4Impact of chronic kidney disease stages on surgical and functional outcomes in robot-assisted partial nephrectomy for localized renal tumors2024 · 7 citations
  5. 5The new surgical robot Hugo™ RAS for total hysterectomy: a pilot study2023 · 6 citations