September 28, 2025JAMA Health Forum34 citationsOpen Access

Benefit-Risk Reporting for FDA-Cleared Artificial Intelligence−Enabled Medical Devices

View Full Paper
JLJohn C. LinBJBhav JainJIJay M. Iyer

Key Points

  • Despite increasing FDA clearance of AI/ML devices, standardized safety and efficacy reporting remain insufficient.
  • Only 1.6% of analyzed AI/ML devices reported data from randomized clinical trials, with many lacking a proper study design.
  • The review covered 691 AI/ML devices, with 489 adverse events reported, underscoring significant safety concerns.
  • Dedicated pathways for regulatory oversight are essential to improve assessment and management of AI/ML device risks.

Abstract

Importance Devices enabled by artificial intelligence (AI) and machine learning (ML) are increasingly used in clinical settings, but there are concerns regarding benefit-risk assessment and surveillance by the US Food and Drug Administration (FDA). Objective To characterize pre- and postmarket efficacy, safety, and risk assessment reporting for FDA-cleared AI/ML devices. Design and Setting This was a cross-sectional study using linked data from FDA decision summaries and approvals databases, the FDA Manufacturer and User Facility Device Experience Database, and the FDA Medical Device Recalls Database for all AI/ML devices cleared by the FDA from September 1995 to July 2023. Data were analyzed from October to November 2024. Main Outcomes and Measures AI/ML reporting of study design, data availability, efficacy, safety, bias assessments, adverse events, device recalls, and risk classification. Results The analysis included data for all 691 AI/ML devices that received FDA clearance through 2023, with 254 (36.8%) cleared in or after 2021. Device summaries often failed to report study designs (323 46.7%), training sample size (368 53.3%), and/or demographic information (660 95.5%). Only 6 devices (1.6%) reported data from randomized clinical trials and 53 (7.7%) from prospective studies. Few premarket summaries contained data published in peer-reviewed journals (272 39.4%) or provided statistical or clinical performance, including sensitivity (166 24.0%), specificity (152 22.0%), and/or patient outcomes (3 lt;1%). Some devices reported safety assessments (195 28.2%), adherence to international safety standards (344 49.8%), and/or risks to health (42 6.1%). In all, 489 adverse events were reported involving 36 (5.2%) devices, including 458 malfunctions, 30 injuries, and 1 death. A total of 40 devices (5.8%) were recalled 113 times, primarily due to software issues. Conclusions and Relevance This cross-sectional study suggests that despite increasing clearance of AI/ML devices, standardized efficacy, safety, and risk assessment by the FDA are lacking. Dedicated regulatory pathways and postmarket surveillance of AI/ML safety events may address these challenges.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Lin et al. (2025) studied this question.

synapsesocial.com/papers/68d9051b41e1c178a14f4dd5https://doi.org/10.1001/jamahealthforum.2025.3351
Ask AI
Helpful
Bookmark
Share
View Full Paper