PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
October 5, 2025Physica Scripta8 citations

Ultra-Sensitive Wide-Angle and Polarization-Independent Terahertz Metamaterial Absorbers for Early Detection of Basal Cell Carcinoma

View Full Paper
AKAnuradha KumariSVS. VincentACAshish Kumar Chowdhary

Key Points

  • Achieving 97% absorption at 3.275 THz indicates high efficiency in terahertz detection methods.
  • The design offers a sensitivity of 0.626 THz/RIU for basal carcinoma cells, underscoring its potential in early cancer diagnosis.
  • Polarization-independent performance supports versatile application across various angles, enhancing usability in clinical settings.
  • Investigations into graphene's chemical potential and thickness effects allow for broader application in detecting biological samples.

Abstract

Abstract Terahertz metamaterial absorbers have come to the forefront of biosensing applications due to the non-ionizing characteristics and sensitivity to weak interactions of the terahertz radiation. This article presents a novel design of graphene-based terahertz metasurface absorber (MSA) aimed at early label-free cancerous cell detection. The design consists of two concentric hexagonal graphene rings placed on top of a SiO 2 dielectric layer, followed by a gold metallic ground plane. We achieve a near-perfect absorption of 97% at 3.275 THz with a Q-factor of 22.061. The simulated spectral characteristics are verified analytically using the impedance matching theory. A near-perfect absorption at the resonant frequency can be attributed to the effective excitation of localized surface plasmon modes. The proposed biosensor demonstrates a sensitivity of 0.622 THz/RIU, and a figure of merit (FoM) of 4.49 RIU⁻¹ in response to the normal cell. On the contrary, it shows a sensitivity of 0.626 THz/RIU, and a FoM of 4.42 RIU⁻¹ in response to the basal carcinoma cells. A parametric study of the thickness and refractive index of the analyte suggests that the proposed design may be applied to the detection of thin films of biological samples. Furthermore, the effect of changes in the chemical potential and relaxation time of Graphene is also investigated. The MSA is polarization-independent and shows wide incident angle stability (up to 60 o ). The sensitivity and FoM calculations suggest that the proposed MSA can outperform recently reported biosensors, potentially leading to a significant improvement in diagnostic accuracy for early-stage cancer detection.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Kumari et al. (2025) studied this question.

synapsesocial.com/papers/68e24e65d6d66a53c2473855https://doi.org/10.1088/1402-4896/ae0f64
Ask AI
Helpful
Bookmark
Share
View Full Paper