In this work, the electrodeposition reaction of Am in AmCl 3 -LiCl-KCl molten salt was studied using voltammetry and chronoamperometry. Electrodeposition of Am was shown to proceed via a two − step reaction scheme, involving the one-electron transfer reduction of Am 3+ to Am 2+ , followed by the two-electron transfer reduction of intermediate Am 2+ to Am 0 . A low Coulombic efficiency of Am deposition was measured despite the Am deposition occurring within the thermodynamic stability window of the supporting LiCl-KCl electrolyte. We hypothesize that the low efficiency is due to out-diffusion of the intermediate Am 2+ species away from the electrode surface. Experimental observations provide evidence of a kinetically − limited electrodeposition reaction, which allows for the loss of intermediate Am 2+ via diffusion leading to Am deposition inefficiency.
No takes yet. Share an insight, caveat, or question.
Kersten et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: