Recently, the application of textile-reinforced concrete (TRC) in thin-walled precast structures has gained significant attention. Among these innovations, the combination of TRC and reinforced concrete (RC) has emerged as an effective method for creating hybrid structural systems. This paper presents the experimental results analyzing the shear behavior of a hybrid deck slab structure consisting of TRC stay-in-place (SiP) formwork and RC components. Shear performance was evaluated using 3-point bending tests on four large-scale specimens with aspect ratios (a/d) varying from 1.6 to 2.3. The average load carried by the TRC SiP formwork prior to failure—due to textile reinforcement rupture—was approximately 26.3 kN, with compressive strains at the top edge ranging from 2.8 to 3.4 ‰, just below the concrete's ultimate strain. The findings demonstrate the versatility of TRC SiP-formwork, highlighting its adaptable cross-section and substantial load-bearing capabilities, making it particularly suitable for composite bridge deck applications. The specimens experienced both shear compression and diagonal shear failures. Moreover, the TRC SiP-formwork effectively mitigated transverse cracking at the interface, enhancing bond strength and improving overall structural performance