Lead-acid batteries (LABs) play a pivotal role in the energy storage sector with applications spanning from starting-ignition-lightning batteries to grid energy storage. Passivation of lead negative electrodes by PbSO4 crystals is a one fundamental mechanism limiting the performance of LAB. In this regard, we developed an electrochemical mathematical model that simulates the nucleation and growth dynamics of PbSO4 crystals on a flat lead electrode, responsible for its passivation. The model considers the electrochemical dissolution of Pb2+ from lead electrode and the ternary transport of lead, bisulfate, and hydrogen ions in H2SO4 electrolyte. We have validated the model with a rich dataset of cyclic voltammetry (CV) responses collected at several scan rates and several concentrations of H2SO4. The model shows remarkable qualitative and quantitative agreement with the experimental data including the onset potential, center, height, and width of the CV peaks, discharge capacity, and particle size. The model is used to give insights on how different physical and operational parameters can influence the electrochemical response of lead negative electrodes.
No takes yet. Share an insight, caveat, or question.
Effat et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:
More from Meeting abstracts/Meeting abstracts (Electrochemical Society. CD-ROM)