The stable and efficient operation of the grid-connected inverter (GCI) is facing severe challenges under the large short-circuit ratio (SCR) fluctuations. In order to ensure the operation quality of the GCI, the dual-mode control was proposed to select the current source mode (CSM) or voltage source mode (VSM) according to the SCR. However, due to the different principles of the dual-mode, when the GCI directly switches from the CSM to the VSM, the grid-injected current and the PCC voltage will have large oscillations. In this paper, a smooth switching dual-mode control method is proposed by using a Kalman Filter observer to suppress the oscillations during mode switching process. The proposed method has been fully verified through simulations and experiments.
No takes yet. Share an insight, caveat, or question.
Cheng et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: