The NG-Test CARBA 5 and Carbapenem-resistant K.N.I.V.O. Detection K-Set are lateral flow assays (LFAs) that rapidly detect five carbapenemases (KPC, NDM, IMP, VIM and OXA-48-like). We evaluated the effect of inoculum size on the performance of these two assays using 27 Enterobacterales isolates. Whole-genome sequencing (WGS) was used as the reference method. Using the NG-Test CARBA 5, eight Serratia spp. and six M. morganii isolates showed false-positive NDM results with a high inoculum. Using the Carbapenem-resistant K.N.I.V.O. Detection K-Set, eight M. morganii, four Serratia spp. and one K. pneumoniae isolates showed false-positive NDM and/or OXA-48-like bands at large inoculum sizes, while the other two M. morganii isolates demonstrated false-positive NDM and OXA-48-like results at all inoculum sizes. The false-positive bands varied in intensity. WGS confirmed that no carbapenemase gene was present. No protein sequence with a ≥50% identity to NDM or OXA-48-like enzymes was found. This study emphasizes the importance of assessing inoculum size in the diagnostic evaluation of LFAs.
No takes yet. Share an insight, caveat, or question.
Lee et al. (2024) studied this question.