PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
June 11, 20247 citationsOpen Access

Validation of GPM DPR rainfall and Drop Size Distributions using disdrometer observations in the Western Mediterranean

View Full Paper
EPEric PeinóJBJoan BechFPFrancesc Polls

Key Points

Key points are not available for this paper at this time.

Abstract

The Dual-Frequency Precipitation Radar (DPR) on the Core GPM satellite provides spaceborne 3-dimensional observations of the precipitation field and surface rainfall rate with quasi global coverage. The present study evaluates the behavior of liquid precipitation intensity, radar reflectivity factor (ZKu and ZKa) and Drop Size Distribution (DSD) parameters (weighted mean diameter Dm and intercept parameter Nw) of the GPM DPR derived products version 07 from 2014 to 2023. Observations from seven Parsivel disdrometers located in different topographic zones in the Western Mediterranean are taken as ground reference. Four matching techniques between satellite estimates and ground level observations were tested, and best results were found for the so-called optimal comparison approach. Overall, GPM DPR products capture well the variability of the observed DSD at different rainfall intensities. However, overestimation of the mean Dm and underestimation of the mean Nw are observed, being much more sensitive to errors in drop diameters larger than 1.5 mm. Moreover, lowest errors were found for radar reflectivity factor and Dm, and highest for Nw and rainfall rate. In addition, the GPM DPR convective and stratiform classification was tested and it was found a substantial overestimation of stratiform cases compared to disdrometer observations.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Peinó et al. (2024) studied this question.

synapsesocial.com/papers/68e6542bb6db6435875e310bhttps://doi.org/10.20944/preprints202406.0597.v1
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Evaluation of GPM DPR Rain Parameters with North Taiwan Disdrometers2023 · 21 citations
  2. 2The Tropical Rainfall Measuring Mission (TRMM) Sensor Package1998 · 2,476 citations
  3. 3Natural Variations in the Analytical Form of the Raindrop Size Distribution1983 · 1,396 citations
  4. 4Climate change and interconnected risks to sustainable development in the Mediterranean2018 · 1,521 citations
  5. 5Deterministic Forecasts of Multi‐Category Events2011 · 7 citations