PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
June 6, 2024Pediatric Nephrology1 citationsOpen Access

Assessment of volume status of pediatric hemodialysis patients

View Full Paper
FFFatina I. FadelDSDoaa M. SalahMMMohamed A. Abdel Mawla

Key Points

Key points are not available for this paper at this time.

Abstract

Abstract Background Accurate volume status assessment and dry weight achievement are the most challenging goals for a nephrologist. We aimed to evaluate the role of ultrasonographic parameters including lung ultrasound and inferior vena cava (IVC) measurements as practical methods of volume status assessment in children on hemodialysis by comparing them with established techniques, such as clinical evaluation and bioimpedance spectroscopy. Methods A prospective cross-sectional study compared pre- and post-dialysis volume status using bioimpedance spectroscopy (BIS) parameters and clinical data with ultrasonographic lung B-lines and IVC parameters in children on regular hemodialysis. Results A total 60 children (mean age 9.4 ± 2.8 years) were enrolled. Twenty patients (33.3%) were clinically overloaded to varying degrees (17 patients had mild to moderate signs of fluid overload and 3 patients had moderate to severe signs of fluid overload). All other patients (66.7%) were clinically euvolemic. Sonographic parameters were significantly lower post-dialysis than pre-dialysis, including lung B-line count and IVC diameter. IVC collapsibility index mean was significantly higher post-dialysis than pre-dialysis. There was a significant correlation between the lung B-line count, IVC parameters, and BIS-measured overhydration both before and after hemodialysis. Nine patients had ≥ 8 B-lines post-dialysis, only three of them were hypertensive. Conclusions Clinical criteria alone are not specific for determining accurate fluid status in pediatric hemodialysis patients. Lung B-line score, IVC parameters, and BIS may be complementary to each other and to clinical data. Lung B-lines outperform IVC measurements and BIS in subclinical volume overload detection in pediatric hemodialysis patients. Graphical abstract

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Fadel et al. (2024) studied this question.

synapsesocial.com/papers/68e65d1eb6db6435875ebc29https://doi.org/10.1007/s00467-024-06409-2
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Comparison and Reproducibility of Techniques for Fluid Status Assessment in Chronic Hemodialysis Patients2013 · 76 citations
  2. 2Variabilidad inter e intraobservador en la valoración ecocardiográfica de la función del ventrículo derecho2010 · 54 citations
  3. 3Inferior vena cava diameter: a useful method for estimation of fluid status in children on haemodialysis2001 · 136 citations
  4. 4Dialysis disequilibrium syndrome2012 · 108 citations
  5. 5Can Nephrologists Use Ultrasound to Evaluate the Inferior Vena Cava A Cross-Sectional Study of the Agreement between a Nephrologist and a Cardiologist2014 · 20 citations