In order to ensure the accuracy and reliability of the test results, the carbon monoxide content in the waste gas of fixed pollution sources was used on the field data. By explaining the steps and principles of the field operation, Establishing a mathematical model for the uncertainty of the carbon monoxide content in the exhaust gas, the main sources of the uncertainty components are analyzed, and the uncertainty assessment of class A and class B is passed. The results show that the main sources of uncertainty components include repetitive measurement, instrument value error and CO standard gas, which are 4.15%, 0.982% and 1.15% respectively; the extended uncertainty is ± 10 (k=2). The results show that under the condition of ensuring the stability of the process emission, increasing the number of field measurement is the key to reduce the uncertainty, which is conducive to improving the quality level of the fixed source waste gas monitoring data.
No takes yet. Share an insight, caveat, or question.
Kang et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: