PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
October 8, 2025Frontiers in Cardiovascular Medicine2 citationsOpen Access

Machine learning algorithms for predicting atrial fibrillation using single-lead data derived from 12-lead ECGs

View Full Paper
JCJi-Hoon ChoiSSSung‐Hee SongJKJongwoo Kim

Key Points

  • The machine learning model achieved an AUROC of 0.801, showing promise in atrial fibrillation prediction.
  • Single-lead ECG data demonstrated comparable performance to the conventional 12-lead model in identifying AF.
  • The model was developed using data from 248,612 ECGs of 106,606 patients, including 11,810 with AF.
  • Lead I outperformed other individual leads in the machine learning application for predicting AF.

Abstract

Background Wearable electrocardiogram (ECG) monitoring devices that utilize single-lead ECG technology have become valuable tools for identifying paroxysmal atrial fibrillation (AF). This study aimed to develop a machine learning (ML) algorithm to predict new-onset AF by training it on single-lead data extracted from 12-lead ECG recordings. Methods and results Patients who underwent 12-lead ECG between January 2010 and December 2021 were classified into two groups based on a review of their medical records and diagnostic codes: the AF group and the normal group. An ML model was created using single-lead ECG data, excluding three augmented leads, and incorporating 60 calculated statistical variables for each of the remaining single leads. The model's performance was assessed using several metrics, including the area under the receiver operating characteristic curve (AUROC), sensitivity, specificity, accuracy, and F1 score. We trained the ML model on 248,612 ECGs collected from 106,606 patients, of whom 11,810 had definite AF. Among the single-lead machine learning models developed from each of the nine individual leads, lead I demonstrated the best performance. The AUROC of the single-lead ECG ML model using lead I was 0.801, while the AUROC of the 12-lead ECG ML model was 0.816. Conclusion The single-lead ECG ML model has shown promise in predicting new-onset atrial fibrillation (AF), particularly with lead I. Its performance is comparable to that of the 12-lead model.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Choi et al. (2025) studied this question.

synapsesocial.com/papers/68e6860af44b9035634c2072https://doi.org/10.3389/fcvm.2025.1612750
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Machine Learning Algorithm to Predict Atrial Fibrillation Using Serial 12‐Lead ECGs Based on Left Atrial Remodeling2024 · 12 citations
  2. 2Atrial Fibrillation Begets Heart Failure and Vice Versa2016 · 884 citations
  3. 3Single-lead electrocardiogram Artificial Intelligence model with risk factors detects atrial fibrillation during sinus rhythm2023 · 24 citations
  4. 4An artificial intelligence–based model for prediction of atrial fibrillation from single-lead sinus rhythm electrocardiograms facilitating screening2023 · 66 citations
  5. 5Artificial intelligence for atrial fibrillation detection, prediction, and treatment: A systematic review of the last decade (2013–2023)2024 · 20 citations