Muon imaging technology is an innovative imaging technique that can be applied in volcano imaging, heavy nuclear material detection, and archaeological research. The Micromegas detector is a promising choice for muon imaging due to its high spatial resolution and large area. However, the large number of readout channels poses a challenge for electronics. In this paper, a compact front-end electronics (FEE) for reading Micromegas detectors is presented. The electronics use a current-based readout chip, ADAS1128, which integrates 128 current amplifiers for multi-channel charge measurement. After noise and calibration tests, detector energy resolution tests were performed using 5.9 keV X-rays. The X-ray full energy peak and Ar escape peak can be observed; the energy resolution of the full energy peak is about 20.23%@5.9 keV. Additionally, a muon image system was set up to verify the imaging capacity of Micromegas detectors. Test results show that the spatial resolution of the system is better than 200 {μ}m. The muon image system can reconstruct the boundaries for objects with a size of 2 cm.