PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
May 18, 2024Nuclear Materials and Energy8 citationsOpen Access

Laser-induced breakdown spectroscopy for helium detection in beryllium coatings

View Full Paper
IJIndrek JõgiPPP. ParisJRJasper Ristkok

Key Points

Key points are not available for this paper at this time.

Abstract

Laser Induced Breakdown Spectroscopy (LIBS) method is considered to be a promising tool for analyzing the retention of hydrogen isotopes (D and T) and helium (He) on the first walls and divertor regions of future fusion reactors. Helium will be produced in DT reactions but could also be used in the initial non-nuclear phases of DEMO concepts. The present study investigates the He detection by LIBS method in the Be coatings simulating the deposits on the divertor plasma-facing components of JET while the results are also relevant for He detection in the deposits of other wall materials. The study was carried out in a vacuum vessel filled with 2–40 mbar argon background gas. It was shown that 2.8 at. % of He was confidently detectable by LIBS at optimized measurement conditions and the estimated limit of detection at used experimental conditions is approximately 0.7 at. %. The intensity of the He emission line at 587.56 nm was the strongest at the center of the laser-induced plasma plume. The He line intensity increased with the pressure of Ar gas but the broadening of the He line and the increase of the background emission and noise set an upper limit to the Ar background pressure usable for He detection. The application of the calibration-free LIBS procedure resulted in the overestimation of the He/Be ratio by several orders of magnitude. The overestimation can be explained by the deviation of LIBS plasma from the local thermodynamic equilibrium, which is caused by the very high excitation energy of He atoms.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Jõgi et al. (2024) studied this question.

synapsesocial.com/papers/68e6970fb6db64358761da7chttps://doi.org/10.1016/j.nme.2024.101677
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Extended pseudo-Voigt function for approximating the Voigt profile2000 · 308 citations
  2. 2Development of a time-of-flight spectrometer at the Ruder Bošković Institute in Zagreb2008 · 66 citations
  3. 3Internal structure and expansion dynamics of laser ablation plumes into ambient gases2003 · 546 citations
  4. 4Investigating helium–deuterium synergies in plasma-exposed tungsten using laser ablation techniques2020 · 14 citations
  5. 5Beryllium-tungsten study on mixed layers obtained by m-HiPIMS/DCMS techniques in a deuterium and nitrogen reactive gas mixture2017 · 21 citations