Cooling water is extensively used in photolithography for temperature control of coating and developing[1]. Water leaks can cause failure in semiconductor manufacturing processes [2], resulting in significant wafer yield loss. Inspecting or replacing all water jackets periodically is time- consuming and costly. Due to a rapid flow of cooling water running at 5l/min in TEL Track [3], it is hard to detect bubbles in the TCU (temperature control unit) return line by ordinary bubble detection methods readily available on the market. A photoelectric sensor with a retro-reflective type can be used to detect high-speed liquid or bubbles in specific applications. When an object, such as a liquid or bubble, passes through the beam of light, the amount of light reflected in the sensor changes, which can trigger an output signal. This paper will present a cost- effective setup of fiber optic evanescent sensors for early detection of water jackets or tubing cracks to eliminate the risk of wafer defects due to potential liquid leaks.
No takes yet. Share an insight, caveat, or question.
Aung et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: