In order to improve the internal heat dissipation efficiency of the proton exchange membrane fuel cell, this paper designs and builds a set of fuel cell heat dissipation system experimental bench with a heat dissipation capacity of 15kW based on the separated heat pipe technology, and investigates the heat dissipation characteristics of the HFE-7100 and ethylene glycol aqueous cooling medium under different condenser processes and different ambient temperatures. The results show that at an ambient temperature of 35°C, under the same condenser flow arrangement, the two-phase heat dissipation efficiency of HFE-7100 is higher than that of glycol aqueous solution liquid cooling, and its heat dissipation and EER (Energy Efficiency Ratio) are increased by 81.2%∼98.8% and 68.2%∼86.6%, respectively. The best effect is achieved when the condenser is 3-process, with two-phase heat dissipation of 14.1kW and EER of 20.5kW/kW, which are 82.8% and 68.9% higher than liquid cooling, respectively. As the ambient temperature rises, the two-phase heat dissipation effect is further improved, and at 50°C ambient temperature, the heat dissipation is 10.44 kW, which is 145% higher than that of liquid cooling, and the EER is 15 kW/kW, which is 132% higher.
No takes yet. Share an insight, caveat, or question.
Bai et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: