Purpose: To determine the efficacy and longevity of patient-specific implants (PSIs) with strut abutment design to rehabilitate bilateral maxillectomy defect. Materials and Methods: Finite Element Analysis was performed on a PSI with strut abutments to repair a patient’s bilateral maxillectomy defect due to COVID associated mucormycosis. Results: The von Mises stress recorded was maximum in the zygomaticomaxillary buttress region, and displacement values were noted to be highest in the posterior-most strut, although both parameters were within acceptable limits, which is favorable. Conclusion: The authors draw the conclusion that a PSI with strut abutments is a workable therapeutic modality for patients with these kinds of abnormalities based on this information.
No takes yet. Share an insight, caveat, or question.
Datarkar et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: