Analytical/quasi-analytical solutions are proposed for a steady, compressible, single-phase flow in a rectilinear duct subjected to heating followed by cooling. The flow is driven by the pressure ratio between an upstream tank and a variable outlet pressure. The article proposes a methodology to determine the full flow behavior, as a function of pressure ratio and heat-flux distribution. Following an analogy done with the study of compressible flows in nozzles, a behavioral classification of non-adiabatic compressible flows is proposed through the definition of critical pressure ratios. It is demonstrated that a critical pressure ratio distinguishes subsonic and supersonic outlet regimes and that there cannot be a steady shock wave in such configuration. The behavior of this critical pressure ratio is studied for limit cases of heat flux, delineating physical boundaries. An abacus is also proposed for a given couple of heating and cooling powers, as both values are needed to characterize the flow. Results are studied for parameters such as pressure ratio and outlet heat power. A short validation of a numerical simulation tool is provided, yielding excellent results and very small relative errors.
No takes yet. Share an insight, caveat, or question.
Schropff et al. (2024) studied this question.
Synapse has enriched one closely related paper. Consider it for comparative context: