Background: An accurate and noninvasive method to determine the preoperative clear-cell renal cell carcinoma (ccRCC) pathological grade is of great significance for surgical program selection and prognosis assessment. Previous studies have shown that diffusion-weighted imaging (DWI) has moderate value in grading ccRCC. But DWI cannot reflect the diffusion of tissue accurately because it is calculated using a monoexponential model. Intravoxel incoherent motion (IVIM) is the biexponential model of DWI. Only a few studies have examined the value of IVIM in grading ccRCC yet with inconsistent results. This study aimed to compare the value of DWI and IVIM in grading ccRCC. Methods: In this study, 96 patients with pathologically confirmed ccRCC were evaluated by DWI and IVIM on a 3-T scanner. According to the World Health Organization/International Society of Urological Pathology (WHO/ISUP) classification system, these patients were divided into two groups: low-grade (grade I and II) and high-grade (grade III and IV) ccRCC. The apparent diffusion coefficient (ADC), true diffusion coefficient (D), pseudodiffusion coefficient (D*), and perfusion fraction of pseudodiffusion (f) values were calculated. The Mann-Whitney test, receiver-operating characteristic (ROC) analysis, and the Delong test were used for statistical evaluations. Results: (I) According to the WHO/ISUP nuclear grading system, 96 patients were divided into low-grade (grade I and II, 45 patients) and high-grade (grade III and IV, 51 patients) groups. (II) Compared with patients of low-grade ccRCC, the ADC and D values of those with high-grade ccRCC decreased while the D* and f values increased (P<0.05). (III) The cutoff value of the ADC, D, D*, and f in distinguishing low-grade from high-grade ccRCC was 1.50×10−3 mm2/s, 1.12×10−3 mm2/s, and 33.19×10−3 mm2/s, 0.31, respectively; the area under the curve (AUC) for the ADC, D, D*, and f values was 0.871, 0.942, 0.621, and 0.894, respectively, with the AUC of the D value being the highest; the sensitivity for the ADC, D, D*, and f values was 94.12%, 92.16%, 47.06%, and 92.16%, respectively; and the specificity for the ADC, D, D*, and f values was 66.67%, 91.11%, 77.78%, and 73.33%, respectively. (IV) Based on the Delong test, AUCD was significantly higher than AUCADC (P=0.02) and AUCD* (P<0.001), but there was no significant difference between AUCD and AUCf (P=0.18). Conclusions: Compared with the monoexponential model DWI, the biexponential model IVIM was more accurate in grading ccRCC.
No takes yet. Share an insight, caveat, or question.
Cao et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: