In this study, a hybrid cooling technology comprising phase change material (PCM) and active cooling was employed for a battery pack arrangement with a circular configuration. The numerical model comprised simulated Li-ion batteries made of aluminium, which generate heat, housed within a cylindrical steel casing filled with a PCM. Numerical simulations were carried out using the ANSYS-FLUENT 2023 R2 edition. A comparative study was conducted on various battery configurations, including 4-battery and 6-battery setups, subjected to constant heat loads of 5W and 15W, cyclic heat loads where batteries generate a constant 5W or 15W for 500 seconds within each cycle, followed by a 500-second interval with no heat load, and charge-discharge cycle analyses. In the latter study, three batteries operated at 5W while one malfunctioning battery operated at 15W. Two configurations were tested, including a single pipe and four pipes. Preliminary results revealed that the hybrid cooling system with a single pipe reached a maximum temperature of 90°C for the malfunctioning battery configuration, whereas the four-pipe configuration resulted in a maximum of 56°C before achieving a steady-state condition. These findings underscore the effectiveness of the proposed cooling mechanism, even when handling heat loads exceeding the batteries’ rated capacities.
No takes yet. Share an insight, caveat, or question.
Majumder et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: