PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 18, 2024Energy Nexus11 citationsOpen Access

Techno-economic analysis of commercial-scale 15 MW on-grid ground solar PV systems in Bakalia: A feasibility study proposed for BPDB

View Full Paper
MNMahdi Hossain NabilJBJoyon BaruaUEUmme Riazul Jannat Eiva

Key Points

Key points are not available for this paper at this time.

Abstract

Renewable energy systems, such as solar power, are becoming increasingly important worldwide due to the limited supply of non-renewable energy sources. Solar power stands out as a practical choice for electricity generation because it's simple to set up and costs less than other renewable options. Solar-based on-grid or grid-tied systems are more effective compared to other PV grid systems due to their more reasonable installation system, favorable maintenance, and less complex system. This study was designed with a solar-based grid-tied system. This study evaluates the performance and economic viability of a 15 MW on-grid photovoltaic (PV) system in Bakalia Char, Chittagong, Bangladesh, and will propose this study for the Bangladesh Power Development Board (BPDB). Developing a clean energy system in Bangladesh is the main purpose of this study. This system performed efficiently, with an 84.03% performance ratio, produced energy of 21510.186 MWh/year and proved economically attractive with a 4.5-year payback period, a competitive electricity cost of 0.024 USD/kWh, and a 389% return on investment(ROI%). Using software like PVsyst and SketchUp ensures precise system design and optimal module placement. Also, use a better PV panel system whose efficiency is higher than that of another PV panel system designed for a similar project. This system boosts local electricity production and aligns with sustainable energy goals. Its success is a valuable model for future solar projects in similar regions facing energy challenges. The system also shows significant environmental benefits, with a projected reduction of approximately 252168.5 tons of CO2 emissions over its operational lifespan.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Nabil et al. (2024) studied this question.

synapsesocial.com/papers/68e7375cb6db6435876b0c4dhttps://doi.org/10.1016/j.nexus.2024.100286
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Impact of the tilt angle, inverter sizing factor and row spacing on the photovoltaic power forecast accuracy2022 · 45 citations
  2. 2Development of a MATLAB/Simulink Model of a Single-Phase Grid-Connected Photovoltaic System2009 · 275 citations
  3. 3A time of use tariff scheme for demand side management of residential energy consumers in Bangladesh2021 · 52 citations
  4. 42016 Saudi Arabia Smart Grid (SASG)2016 · 9 citations
  5. 5SketchUp, Explained2018 · 1 citations