Currently, microchannels are widely used in liquid-liquid heterogeneous mass transfer systems due to its excellent mass transfer performance. However, because of the passive mixing principle of traditional microchannels, the improvement of mass transfer performance has a bottleneck. This work proposes a novel rotating millimeter channel reactor (RMCR), capable of achieving liquid-liquid heterogeneous mass transfer enhance by centrifugal force. Three typical flow patterns of slug flow, parallel-droplet flow, and parallel flow in the RMCR were observed by high-speed photography technology. The volumetric mass transfer coefficient ( K O a ) of the RMCR increased with the increase of the total volumetric flow rate and rotational speed ( N ) increased. Compared with N = 0 r/min, the K O a of the RMCR increases by 61.5 % at 200 r/min, ranging from 0.013 to 0.021 s −1 . The RMCR proposed in this work is expected to be applied to the liquid-liquid heterogeneous mass transfer system with high processing capacity and easy plugging.
No takes yet. Share an insight, caveat, or question.
Liang et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: