Metallic contamination has long been reported as a source of defects for most semiconductor devices, and its impacts on complementary metal-oxide-semiconductor (CMOS) image sensors (CISs) are especially detrimental. These contaminants could be introduced during the CIS fabrication, such as ion implantation process [1]–[2]. Wafer surface concentration of certain noble metals, including Au, Ag, and Pt, needs to be controlled to no more than 0.05 to 0.2 ppt [6]. Conventional methods of metal trace analysis involve chemically collecting these elements into a scanning solution, and analyzing the diluted scanning solution by inductively coupled plasma mass spectroscopy (ICP-MS). However, detecting the concentration of noble metals on wafer surface has been particularly challenging, due to their low solubility in scanning solutions. In this paper, the authors proposed a method to effectively collect the noble metals, especially silver and gold, with an aqua regia (AR) based scanning solution to increase the collection efficiency (CE). Combined with a vapor phase decomposition (VPD) treatment of the wafer surface, and an integrated ICP-MS analysis, our fully automated method of AR based noble metal collection is of great importance to control the noble metal contamination for CIS manufacturing.
No takes yet. Share an insight, caveat, or question.
Huang et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: