This study explores techniques to mitigate interference in assessing functions related to AM radio wave signals in digital media receivers. Signal transmission cable testing focused on BNC RG59 75-ohm cables with length of 300 mm. Six methods were employed: Method 1 used a Ferrite core, Method 2 used copper tape, Method 3 connected a grounding wire, Method 4 combined grounding wire connection with a Ferrite core, Method 5 combined grounding wire connection with copper tape, and Method 6 combined grounding wire connection with both a Ferrite Core and copper tape. The result has been shown that Method 6 yielded optimal results, with AM 1000 kHz Usable Sens, AM Interstation Noise L, and AM Interstation Noise R functions differing from reference values by −3.53 dBm, −5.05 dBm, and −5.26 dBm, respectively, emphasizing its efficacy in enhancing the assessed functions.