March 1, 2024The Journal of the Acoustical Society of America1 citations

Designing an acoustical test fixture to evaluate the objective occlusion effect

View Full Paper
ODOlivier DoutresYLYu LuanMCMarc-Olivier Cyr-Desroches

Key Points

Key points are not available for this paper at this time.

Abstract

Earplugs are commonly used to prevent noise-induced hearing loss. However, their effectiveness is often hindered by the discomfort they cause, impacting consistent and correct use. An important acoustical discomfort, known as the occlusion effect, arises from an increased perception of bone-conducted physiological sounds (such as one's own voice, breathing, and chewing) when the ear canal is occluded. To objectively assess this discomfort, the study proposes the use of an acoustical test fixture (ATF) that avoids direct measurements on human participants. The ATF employs an anatomically realistic truncated outer ear, incorporating soft tissues, cartilage, and bone components to replicate the outer ear's bone conduction path, crucial for occlusion effect assessments. The study demonstrates that the proposed ATF can replicate key effects observed in objective ccclusion effect (OE) measurements on human participants, including significant OE at low frequencies diminishing with increasing frequency, reduction of OE with greater insertion depths, and distinctions among various earplug types—especially noticeable at deeper insertions. Furthermore, a computationally efficient finite element method-based virtual tester for the ATF is developed and validated.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Doutres et al. (2024) studied this question.

synapsesocial.com/papers/68e76bd8b6db6435876e1e57https://doi.org/10.1121/10.0026818
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Meta-earplugs: Innovative concepts for alleviating the occlusion effect2024 · 1 citations
  2. 2An active control strategy to reduce acoustic occlusion in in-ear devices2025
  3. 3Evaluation of a multi-function in-ear device performance in the presence of impulse noise using acoustic test fixtures2024 · 1 citations
  4. 4Methods to experimentally characterize the own-voice-generated objective occlusion effect induced by hearables2025