PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
October 12, 2025Microsystems & Nanoengineering4 citationsOpen Access

A microfluidic platform for the co-culturing of microtissues with continuously recirculating suspension cells

View Full Paper
CLChristian LohaszTHTamara HäfeliDHDzhansu Hasanova

Key Points

  • The hiFlow chip maintains cell viability and interactions for over 6 days, enhancing in vitro modeling.
  • Validation involved various microtissues and primary immune cells monitored via high-resolution microscopy.
  • Continuous medium flow prevents sedimentation and accumulation of cells, improving interaction fidelity.
  • Assays demonstrated potential for predicting responses to antibody treatments against diffuse midline glioma.

Abstract

In vitro evaluation of novel therapeutic approaches often fails to reliably predict efficacy and toxicity, especially when recapitulating conditions involving recirculating cells. Current testing strategies are often based on static co-culturing of cells in suspension and 3D tissue models, where cell sedimentation on the target tissue can occur. The observed effects may then mostly be a consequence of sedimentation and of the corresponding forced cell-tissue interactions. The realization of continuous medium flow helps to better recapitulate physiological conditions and cell-tissue interactions. To tackle current limitations of perfused organ-on-chip approaches, we developed a microfluidic chip and operation concept, which prevents undesired sedimentation and accumulation of suspended cells during multiple days by relying on gravity-driven perfusion. Our platform, which we termed "human immune flow (hiFlow) chip", enables to co-culture cells in suspension with up to 7 preformed microtissue models. Here, we present the design principle and operation of the platform, and we validate its performance by culturing cells and microtissues of a variety of different origins. Cells and tissues could be monitored on chip via high-resolution microscopy, while cell suspensions and microtissues could be easily retrieved for off-chip analysis. Our results demonstrate that primary immune cells and a range of different spheroid models of healthy and diseased tissues can be maintained for over 6 days on chip. As proof-of-concept cell-tissue interaction assay, we used an antibody treatment against diffuse midline glioma, a highly aggressive pediatric tumor. We are confident that our platform will help to increase the prediction power of in vitro preclinical testing of novel therapeutics that rely on the interaction of circulating cells with organ tissues.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Lohasz et al. (2025) studied this question.

synapsesocial.com/papers/68ebffcfdef9fcb308ff25e5https://doi.org/10.1038/s41378-025-01028-9
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Breast cancer-on-chip for patient-specific efficacy and safety testing of CAR-T cells2024 · 108 citations
  2. 2Intestinal barrier dysfunction orchestrates the onset of inflammatory host–microbiome cross-talk in a human gut inflammation-on-a-chip2018 · 307 citations
  3. 3Optimized Protocols for In-Vitro T-Cell-Dependent and T-Cell-Independent Activation for B-Cell Differentiation Studies Using Limited Cells2022 · 28 citations
  4. 4Interleukin 2 and its receptors: recent advances and new immunological functions1996 · 233 citations
  5. 5Evaluation of a 12‐color flow cytometry panel to study lymphocyte, monocyte, and dendritic cell subsets in humans2010 · 236 citations