PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
October 19, 2025Journal of Proteome Research7 citationsOpen Access

Multiplexed Nanoparticle Protein Corona Enables Accurate and Precise Deep Plasma Proteomics

View Full Paper
THTing HuangJWJian WangASAlexey Stukalov

Key Points

  • The Proteograph Product Suite enables accurate detection of over 7,000 plasma proteins in studies.
  • Fold change accuracy was maintained, quantifying 3.5 times more proteins than alternative methods.
  • Evaluation used multispecies spikes to assess linearity and lower limits of quantification across multiple platforms.
  • The method shows minimal variation in protein intensity, suggesting high precision across different nanoparticle batches.

Abstract

The Proteograph Product Suite, a multiplexed nanoparticle (NP) protein corona-based workflow, substantially improves the depth of detection of proteins by mass spectrometry (MS) by compressing the dynamic range of protein abundances. Here, we evaluate its quantitative performance and suitability for large-scale studies. Using multispecies spike-in experiments, we assessed fold change accuracy, linearity, precision, and the lower limit of quantification (LLOQ) across multiple MS platforms. Combined with the Orbitrap Astral MS, the Proteograph XT assay enabled identification of more than 7,000 plasma proteins. In mixed-species dilution experiments, fold change accuracy was preserved, with Proteograph quantifying 3.5 times more proteins than the Neat plasma workflow at the same fold change error threshold. Similar accuracy was observed with the Orbitrap Exploris 480 MS, and we also demonstrate that different proteome backgrounds do not impact the accuracy. Data produced with NPs from the four distinct NP batches (each supporting >100,000 assays) showed only a 4% increase in protein intensity CV across batches. Together, these results demonstrate that the Proteograph Product Suite provides depth as well as quantitative accuracy and precision to power new biomarker discovery and biological understanding in population-scale plasma proteomics cohorts.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Huang et al. (2025) studied this question.

synapsesocial.com/papers/68f43ef4854d1061a58abb4ehttps://doi.org/10.1021/acs.jproteome.5c00729
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Frontiers in plasma proteome profiling platforms: innovations and applications2024 · 26 citations
  2. 2Impact of Sample Preparation Strategies on the Quantitative Accuracy of Low-Abundance Serum Proteins in Shotgun Proteomics2025 · 10 citations
  3. 3Recommendations for Quantitative Data-Independent Acquisition (DIA) Proteomics using Controlled Quantitative Experiments (CQEs)2025 · 4 citations
  4. 4The Clinical Plasma Proteome: A Survey of Clinical Assays for Proteins in Plasma and Serum2009 · 579 citations
  5. 5Mass spectrometry-based proteomics2003 · 6,943 citations