PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
November 30, 2025Materials3 citationsOpen Access

Nanomechanical and Adhesive Behavior of Electrophoretically Deposited Hydroxyapatite- and Chitosan-Based Coatings on Ti13Zr13Nb Alloy

View Full Paper
MBMichał Bartmański

Key Points

  • Chitosan–Cu coatings demonstrated the highest hardness up to 8.2 GPa, indicating superior mechanical properties.
  • Nanoindentation tests confirmed that Chitosan–HAp coatings are softer with a hardness between 0.05 and 0.13 GPa due to their polymer-dominated structure.
  • Electrophoretic deposition with varying parameters was employed to optimize coating behaviors on titanium substrates.
  • The findings underscore the importance of surface treatments for improving adhesion in bioactive coatings for titanium applications.

Abstract

This work reports on the effects of surface pre-treatment and EPD process parameters on the nanomechanical and adhesive performance of chitosan-based composite coatings fabricated on a Ti13Zr13Nb alloy. Three different coating systems were prepared: chitosan–Cu (series A), chitosan–HAp (series B), and HAp–Cu (series C). Coatings were deposited from suspensions at different voltages (10–30 V) and for various times (1–2 min) onto polished, anodized, and laser surface-treated titanium alloy substrates. Microstructural, nanomechanical, and adhesion properties were characterized by means of SEM, nanoindentation, and nanoscratch testing, respectively. Chitosan–Cu coatings exhibited the highest hardness (up to 8.2 GPa) and stiffness due to the homogeneous dispersion of Cu nanoparticles and strong interfacial bonding to the underlying anodized TiO2 layer. Chitosan–HAp coatings were softer (0.05–0.13 GPa) and highly plastic, particularly after laser surface treatment due to their specific porous, polymer-dominated structure. HAp–Cu coatings exhibited an intermediate mechanical behavior with a hardness between 0.1 GPa and 2.9 GPa and enhanced elastic recovery (Wp/We ≈ 3.5–4.7), particularly for anodized substrates. The nanoscratch test results showed that the HAp–Cu coatings exhibited the highest adhesion Lc (≈150–173 mN), confirming a synergistic effect of hybrid composition and heat treatment on interfacial toughness. The present data demonstrate that the optimization of anodizing and EPD processing parameters allows for the manipulation of the mechanical integrity and adhesion of bioactive chitosan-based coatings for titanium biomedical applications.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Michał Bartmański (2025) studied this question.

synapsesocial.com/papers/692b94341d383f2b2a378773https://doi.org/10.3390/ma18235323
Ask AI
Helpful
Bookmark
Share
View Full Paper