PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
December 4, 2025Biomedicines2 citationsOpen Access

Reporting of Perirenal Hematoma Size After Ultrasound-Guided Renal Biopsy in Adults: A Scoping Review

View Full Paper
PBPiotr BiałekWBWeronika BanasikADAdam Dobek

Key Points

  • Perirenal hematoma size after renal biopsy correlates with adverse outcomes, including transfusion.
  • Quantitative assessment in 51 studies primarily used ultrasound for measuring perirenal hematoma size.
  • Standardized methods for measuring hematoma size are lacking, raising clinical implications.
  • Factors influencing larger hematomas include needle gauge, coagulopathy, and impaired kidney function.

Abstract

Introduction: Percutaneous renal biopsy (PRB) is the gold standard for diagnosing nephropathies, but it carries a risk of bleeding complications, mainly perinephric hematomas (PHs). While PH incidence is often reported, the significance of PH size remains insufficiently explored. This scoping review systematically mapped the evidence on PH size after ultrasound-guided PRB in adults, focusing on imaging modalities, measurement methods, the definition of ‘large’ PH, factors influencing PH size, and its clinical implications. Materials and Methods: Following the Joanna Briggs Institute methodology, we searched PubMed/MEDLINE, Embase, Cochrane CENTRAL, and Scopus through 27 August 2025. Eligible studies included at least 50 adult subjects undergoing ultrasound-guided PRB with quantitative, imaging-based assessment of PH size. Results: Fifty-one studies met the inclusion criteria. Almost all relied on ultrasound, with only one using computed tomography. PH size was measured using heterogeneous methods, most often one-dimensional diameters, less frequently surface area or volumetry, with no standardization. Reported PH frequencies varied substantially across studies (1.1–85%), likely reflecting differences in imaging protocols, timing, and reporting thresholds. Several studies proposed PH size thresholds (e.g., diameter ≥ 2–3 cm, volume ≥ 40–85 mL) linked to adverse outcomes such as transfusion or hemodynamic instability. Factors associated with larger PHs included needle gauge, number of passes, impaired kidney function, coagulopathy, and certain histopathologies. Conclusions: PH size has prognostic value beyond incidence alone. Standardized measurement and reporting are needed to clarify its clinical relevance after PRB.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Białek et al. (2025) studied this question.

synapsesocial.com/papers/6930e8dbea1aef094cca3cbdhttps://doi.org/10.3390/biomedicines13122943
Ask AI
Helpful
Bookmark
Share
View Full Paper