Ethyl chloride, a volatile anesthetic with high abuse potential, remains forensically undercharacterized postmortem. In an inhalation model (n = 30), male Wistar rats were exposed to 86,000 ppm ethyl chloride under real-time PID monitoring; blood, lung, liver and brain (plus exploratory adipose, kidney, muscle) were sampled at 0, 2, 4, 6 and 12 h postmortem. A matrix-matched HS-GC-FID method was validated (Eurochem): linearity (R2 = 0.9947–0.9965), LOD 0.01–0.02 ng/μL, LOQ 0.04–0.06 ng/μL, precision RSD 3.9–5.1%, recovery 90–104%, full selectivity against common volatiles. Lung yielded the highest concentrations overall; a significant decline occurred in lung between 2 h and 4 h (Pillai’s Trace p = 0.034). Concentrations became increasingly irregular ≥6 h across tissues. Early autopsy sampling, preferably within ≤6 h, optimizes ethyl chloride detectability. The validated matrix-matched HS-GC-FID protocol provides a cost-effective, robust alternative to MS platforms for volatile screening in routine forensic practice and supports prioritizing lung for analysis.
No takes yet. Share an insight, caveat, or question.
Aydogan et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: