This study develops a systematic kinematic upper-bound framework to evaluate the ultimate bearing capacity and failure mechanisms of prefabricated cast-in-place slab–wall joints in overlapped metro stations. Recognizing the complex shear–compression interaction in these critical structural nodes, a novel three-dimensional short-block shear failure model is established based on the principle of energy balance. The analysis employs a modified Mohr–Coulomb strength criterion incorporating a finite tensile strength cut-off, enabling more accurate representation of cracking and tensile resistance effects. Analytical solutions are derived to predict the ultimate capacity and critical failure angle, followed by a comprehensive parametric analysis. The results reveal that cross-sectional dimensions dominate the bearing capacity, while the internal friction angle and tensile-to-compressive strength ratio significantly influence both the magnitude and mode of failure. A narrower load distribution width enhances capacity and reduces the optimal failure angle. Overall, the proposed 3D model provides a rigorous and efficient theoretical tool for the design optimization and safety assessment of prefabricated underground structures.