Key result
Barostim Neo lowers BP in resistant hypertension with fewer complications than Rheos.
Why the study?
Resistant hypertension affects 10–30% of hypertensive patients with elevated cardiovascular risks, prompting evaluation of novel autonomic-targeting carotid baroreceptor devices when conventional treatments fail.
Do carotid devices reduce blood pressure in patients with resistant hypertension?
Do carotid devices reduce blood pressure in patients with resistant hypertension?
Carotid baroreceptor devices effectively reduce blood pressure in resistant hypertension, with second-generation devices like Barostim Neo offering an improved safety profile.
Supports Barostim Neo preference over Rheos for resistant hypertension; confirms improved safety in systematic review of carotid devices.
Background Resistant hypertension (RHT) affects 10–30% of hypertensive patients, posing a significant challenge, as it leads to greater cardiovascular comorbidities and mortality. Baroreceptor-based therapies, targeting the autonomic nervous system, represent a novel approach for managing RHT when conventional treatments fail. Objective To evaluate the efficacy, safety, and future potential of carotid devices, including Rheos, Barostim Neo, and MobiusHD, in reducing blood pressure (BP) in patients with RHT. Methods A PRISMA-guided search of PubMed/Medline, Scopus, and Cochrane databases was conducted to identify studies on carotid baroreceptor devices up to August 2024. Studies were screened for original data on device efficacy and safety, excluding case reports, abstracts, and non-English publications. Data on study design, patient characteristics, and outcomes were extracted and analyzed. Results Sixteen studies covering Rheos (n=8), Barostim Neo (n=5), and MobiusHD (n=3) were included. Rheos demonstrated significant BP reductions in phase II and III trials but was associated with procedural complications due to its bilateral design. Barostim Neo, a second-generation device, showed comparable efficacy, with a lower complication rate and better compatibility with cardiac devices. MobiusHD, a mechanical endovascular implant, significantly reduced BP over 3 years of follow-up but exhibited procedural risks, such as transient ischemic attacks. Conclusion Carotid devices offer a promising solution for managing RHT, with Barostim Neo emerging as a safer alternative than Rheos. While MobiusHD demonstrates efficacy, further trials are needed to confirm its safety. Additional studies with standardized trial designs and long-term follow-ups will enhance our understanding of the role of carotid-based therapies in hypertension management.
No takes yet. Share an insight, caveat, or question.
Kayir et al. (2026) studied this question. Barostim Neo significantly reduced blood pressure in patients with resistant hypertension while having a lower complication rate than Rheos.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: