Comparative analysis shows RAG model improves treatment recommendations in GI oncology, highlighting LLM evidence source impact.
805 Background: Adherence to NCCN guidelines in GI oncology is inconsistent, and large language models (LLMs) can stray from evidence-based care via hallucinations or outdated references. We examined whether an LLM’s evidence source influences its decision support quality by comparing baseline GPT-4 (O1), a retrieval-augmented model anchored to NCCN GI guidelines (RAG; O2), and an OpenEvidence model retrieving broadly from high-impact journals (O3). Methods: Fifty GI oncology case vignettes were used to test each model (O3 failed to produce output for 2 cases). Outputs were scored with a modified Generative Performance Score (mGPS, range -1.0 to 1.0), combining Guideline Concordance (five-tier rubric from non-concordant to current standard therapy, focusing on correct regimen, required qualifiers, and recognition of missing information) and Hallucination Severity (deductions 0 to -1.0 for minor to critical errors such as fabricated trials, unsafe doses, or incorrect biomarker–therapy links). Each output’s readability and rationale clarity were rated on a 5-point Likert scale. Two oncologists independently scored all cases with substantial agreement (Cohen’s κ = 0.74). We used repeated-measures ANOVA to compare performance across models (using cases where all three outputs were available). Results: For mGPS, mean scores (±SD) were: O1 0.53 ± 0.37; O2 0.70 ± 0.45; O3 0.30 ± 0.45. The difference across models was significant (F(2,90) = 18.62, p < 0.000001), with O2 scoring highest. Readability/rationale clarity was also highest for O2 (mean 4.12 vs 3.38 for O1 and 3.06 for O3). Hallucination severity was lowest with O2, whereas O1 and O3 outputs more often contained serious errors, consistent with broad retrieval increasing off-target information. Conclusions: An LLM’s evidence source materially impacts its clinical performance. The NCCN-anchored RAG model (O2) produced the most guideline-concordant treatment recommendations with the clearest rationale and fewest hallucinations, outperforming both baseline GPT-4 (O1) and the OpenEvidence model (O3). These findings suggest that grounding LLMs in a single up-to-date guideline repository (e.g., NCCN) can limit off-target or outdated information and unsafe suggestions, whereas pulling from a broad, heterogeneous literature increases the risk of hallucinations and misapplied evidence.
No takes yet. Share an insight, caveat, or question.
Yost et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: