First-principles simulation reveals enhanced radiation shielding in TaS2 composites, suggesting promising applications for gamma-ray shielding.
High atomic number (Z) fillers in polymer matrices provide lightweight alternatives to conventional radiation shielding. Previous studies have examined fillers such as CdO, \(WO_3\) , and \(Bi_2O_3\) . However, no prior work has investigated tantalum disulfide ( \(TaS_2\) ) in polymer composites for gamma-ray shielding, leaving a clear gap in the literature. Here, we report the photon attenuation performance of high-density polyethylene (HDPE) composites containing 10–50 wt% \(TaS_2\) over 0.06–2.0 MeV, evaluated by Geant4 Monte Carlo simulations and validated with XCOM data. At 80 keV, where enhancement is most pronounced, the 50 wt% composite achieved a mass attenuation coefficient of 2.88 ± 0.04 \(cm^2\) /g, corresponding to a 15.9 ± 0.21 improvement over pure HDPE. Composites with 35, 20, and 10 wt% \(TaS_2\) showed enhancements of 11.55 ± 0.05, 7.07 ± 0.03, and 4.04 ± 0.02 times, respectively. Benchmarking against micro-CdO–HDPE confirmed competitive or superior attenuation across the photon spectrum. These results establish TaS 2 –HDPE as a tunable, non-toxic, and effective candidate for next-generation radiation shielding applications.