Why the study?
A computer-aided diagnosis system is required to continuously monitor cardiac patients and automatically detect heart diseases.
Answers are grounded in this paper and cite their sources.
A novel FPGA-based ECG feature extraction architecture achieves >99% accuracy for QRS, P-wave, and T-wave detection, demonstrating suitability for real-time continuous cardiac monitoring.
Nowadays, a computer-aided diagnosis system is required to monitor the cardiac patients continuously and detecting the heart diseases automatically. In this paper, a new field programmable gate array-based morphological feature extraction approach is proposed for electrocardiogram signal analysis. The proposed architecture is mainly based on the Generalized Synchrosqueezing transform but a detrended fluctuation analyzer is applied in the reconstruction stage for capturing the maximum information of QRS complexes and P-waves by eliminating a set of noisy intrinsic modes. Then, a correntropy envelope is determined from the QRS enhanced signal for localizing the QRS region accurately. Also, an adaptive heuristic framework is introduced to detect the true P-wave from the P-wave enhanced reconstructed signal by analyzing both the positive and negative amplitudes. In addition, a root mean square Error estimation-based adaptive thresholding approach is used to estimate the T-wave after removing the P-QRS complexes. The proposed architecture has been implemented on field programmable gate array using the Xilinx Vertex 7 platform. The performance of the proposed architecture is validated by performing a comparative study between the resultant performances and those attained with state-of-the-art feature descriptors, in terms of Sensitivity, accuracy, positive prediction, error rate and field programmable gate array resources estimation. The proposed sensitivity, accuracy and positive prediction are 99.84%, 99.85% and 99.86% for QRS detection approach. The proposed sensitivity, accuracy and positive prediction are 99.45%, 99.23% and 99.78% for P-wave detection approach. The proposed sensitivity, accuracy and positive prediction are 99.58%, 99.65% and 100% for T-wave detection approach. The simulation results show that the proposed architecture overtakes existing designs and minimizes hardware complexity, which proves the suitability of this approach on real-time applications of electrocardiogram signals.
No takes yet. Share an insight, caveat, or question.
Ganatra et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: