PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
October 12, 2024Applied Sciences16 citationsOpen Access

Intra- and Interpatient ECG Heartbeat Classification Based on Multimodal Convolutional Neural Networks with an Adaptive Attention Mechanism

ÍPÍtalo Flexa Di PaoloACAdriana Castro

Key Result

The multimodal CNN framework achieved 99.70% accuracy for intrapatient ECG heartbeat classification using two leads, outperforming state-of-the-art systems.

Structured PICO

P
Population
ECG signals from the MIT-BIH public database
I
Intervention
Multimodal convolutional neural network (CNN) with an adaptive attention mechanism
O
Outcome
Arrhythmia classification performance (accuracy, precision, sensitivity, specificity, F1 score)

A multimodal CNN with an adaptive attention mechanism demonstrates high accuracy in classifying cardiac arrhythmias from ECG signals, particularly when using two ECG leads.

Abstract

Echocardiography (ECG) is a noninvasive technology that is widely used for recording heartbeats and diagnosing cardiac arrhythmias. However, interpreting ECG signals is challenging and may require substantial time from medical specialists. The evolution of technology and artificial intelligence has led to advances in the study and development of automatic arrhythmia classification systems to aid in medical diagnoses. Within this context, this paper introduces a framework for classifying cardiac arrhythmias on the basis of a multimodal convolutional neural network (CNN) with an adaptive attention mechanism. ECG signal segments are transformed into images via the Hilbert space-filling curve (HSFC) and recurrence plot (RP) techniques. The framework is developed and evaluated using the MIT-BIH public database in alignment with AAMI guidelines (ANSI/AAMI EC57). The evaluations accounted for interpatient and intrapatient paradigms, considering variations in the input structure related to the number of ECG leads (lead MLII and V1 + MLII). The results indicate that the framework is competitive with those in state-of-the-art studies, particularly for two ECG leads. The accuracy, precision, sensitivity, specificity and F1 score are 98.48%, 94.15%, 80.23%, 96.34% and 81.91%, respectively, for the interpatient paradigm and 99.70%, 98.01%, 97.26%, 99.28% and 97.64%, respectively, for the intrapatient paradigm.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Paolo et al. (2024) studied this question. The multimodal CNN framework achieved 99.70% accuracy for intrapatient ECG heartbeat classification using two leads, outperforming state-of-the-art systems.

synapsesocial.com/papers/69696f24d48283a389c7c27ehttps://doi.org/10.3390/app14209307
Ask AI
Helpful
Bookmark
Share
View Full Paper