Accurate prediction of subway-induced environmental vibrations for unopened lines remains a significant challenge due to the difficulty in determining appropriate excitation inputs. To address this issue, this study proposes an excitation modification method based on field measurements and numerical simulations. First, field measurements were conducted on a subway line in Shanghai to analyze vibration propagation characteristics and validate a two-dimensional finite element model (FEM). Subsequently, based on the validated model, frequency-band excitation modification formulas were derived. Distinct from existing empirical approaches that often rely on simple statistical scaling, the proposed method utilizes parametric numerical analyses to determine frequency-dependent correction coefficients for four key parameters: tunnel burial depth, tunnel diameter, soil properties, and train speed. The reliability of the proposed method was verified through theoretical analysis and an engineering application. The results demonstrate that the proposed method improves prediction accuracy for tunnels in similar soft soil regions, reducing the prediction error from 10.1% to 5.2% in the engineering case study. Furthermore, parametric sensitivity analysis reveals that ground vibration levels generally decrease with increases in burial depth, tunnel diameter, and soil stiffness, while exhibiting an increase with train speed. This study improves the reliability of vibration prediction in the absence of direct measurements and provides a practical tool for early-stage design and vibration mitigation for unopened lines.
Zhang et al. (Thu,) studied this question.