In the eddy current testing (ECT) of magnetized ferromagnetic pipelines, permeability perturbations near defects cause magnetic distortion that primarily modulates the imaginary part of the ECT sensor’s impedance, leading to confusion between inner and outer wall defect signals. To address this interference, this study thoroughly analyzes the modulation mechanism of permeability changes on impedance and investigates the feasibility of detecting solely the real part to enhance discrimination reliability. This understanding leads to the proposal of a solution employing an LC resonant circuit, capitalizing on its characteristic of zero imaginary part impedance at the resonant frequency, to effectively suppress the permeability-related signal interference. Experimental results demonstrate the effectiveness of the proposed approach: the magnetization response test confirms the insensitivity of the LC sensor to permeability perturbations, and the defect discrimination experiment shows that the sensor achieves a standard deviation ratio of 2.25 and a peak-to-peak ratio of 4.42 between inner and outer wall defect signals. The findings indicate that the LC resonant sensor can reliably distinguish between inner and outer wall defects through simple amplitude thresholding, thereby improving the reliability of inspections for magnetized pipelines in industrial applications.