January 23, 2026Arabian Journal of Chemistry0 citationsOpen Access

Intramolecular charge transfer-induced fluorescence enhancement of carbon dots for rapid detection of sugammadex sodium and clinical injection sample analysis

View Full Paper
ZJZiye JingYCYing ChengLJLiyuan Jiao

Key Points

  • This research aims to develop a new fluorescent detection method for sugammadex sodium using carbon dots.
  • Designed a fluorescence detection method using nitrogen-doped carbon dots (CDs)
  • Studied intermolecular charge transfer processes between CDs and sugammadex sodium (SUG)
  • Optimized detection conditions for improved sensitivity and selectivity
  • Achieved a linear detection range of 0.001−0.07 and 0.07−0.5 g/L
  • Established a detection limit of 0.44 mg/L for SUG
  • Demonstrated accuracy in analyzing clinical injection samples with the new method

Abstract

In order to improve the current analytical method for the detection of sugammadex sodium (SUG), the common clinical neuromuscular blockade reversal agent, a carbon dots (CDs) based fluorescent detection method was designed and developed in this work. Nitrogen-doped CDs were selected as the fluorescence nanomaterials considering the unique combination of SUG with amino-steroid drugs. The fluorescence of CDs was efficiently enhanced once interacting with SUG and the underlying mechanism was studied to be the intermolecular charge transfer process between −NH 2 in CDs and −COOH in SUG. Therefore, the novel fluorescence detection method was established according to the sensitive response of CDs toward SUG. Under the optimized conditions, the linear ranges of 0.001−0.07 and 0.07−0.5 g/L was achieved with a detection limit of 0.44 mg/L. Furthermore, the method was applied to the clinical injection sample analysis and accurate results with validity was obtained. The fluorescence detection method with sensitivity and selectivity for SUG assay was proposed in this work. Compared to the traditional analytical method for SUG like chromatography and mass spectrometry, the merits of this fluorescence method, quick response and handy operation, made it a powerful assay for pharmaceutical analysis, improving the rapid analysis for SUG pharmaceutical.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Jing et al. (2026) studied this question.

synapsesocial.com/papers/69731005c8125b09b0d1fcc7https://doi.org/10.25259/ajc_433_2025
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1N, S, Br co-doped carbon dots: One-step synthesis and fluorescent detection of 6-mercaptopurine in tablet2023 · 17 citations
  2. 2Fluorescent carbon dots for discriminating cell types: a review2024 · 10 citations
  3. 3Carbon dots-doped melamine–formaldehyde microsphere as a dual functional material for sensing and adsorption of oxytetracycline2024 · 7 citations
  4. 4A highly sensitive coumarin-based fluorescent probe for visual detection of Cu2+ in aqueous solution and its bioimaging in living cells2023 · 30 citations
  5. 5Machine Learning-Assisted Biomass-Derived Carbon Dots as Fluorescent Sensor Array for Discrimination of Warfarin and Its Metabolites2025 · 6 citations